COMMAND 200A – 1600A

สวิตช์ตัดวงจรขนาด 200A ถึง 1600A

K1 K2 K3
100A 3P 590.K10003B
3P+N 590.K10005B
125A 3P 590.K12503B
3P+N 590.K12505B
160A 3P 590.K16003B-S 590.K16003B
3P+N 590.K16005B-S 590.K16005B
200A 3P 590.K20003B
3P+N 590.K20005B
250A 3P 590.K25003B
3P+N 590.K25005B
315A 3P 590.K31503B
3P+N 590.K31505B
400A 3P 590.K40003B
3P+N 590.K40005B
500A 3P 590.K50003B
3P+N 590.K50005B
K4 K5 K6
630A 3P 590.K63003B
3P+N 590.K63005B
800A 3P 590.K80003B
3P+N 590.K80005B
10000A 3P 590.K100003B
3P+N 590.K100005B
1250A 3P 590.K125003B
3P+N 590.K125005B
1600A 3P 590.K160003B
3P+N 590.K160005B

 

  • K1, K2, K3, K4, K5, K6 Base mounting screws fixing

 

คุณสมบัติทางเทคนิค
Switch size K1 K2 K3 K4 K5 K6
Rated current in 100 125 160 160 200 250 315 400 500 630 800 1000 1250 1600
Rated insulation voltage                   Ui VAC 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
Rated impulse withstand voltage        Uimp kV 8 8 8 12 12 12 12 12 12 12 12 12 12 12
Thermal current                             lth/lthe A 100 125 160 160 200 250 315 400 500 800 800 1000 1250 1600
AC21A

Resistive loads,
including moderate overloads

415V A 100 125 125/160 160 200 250 315 400 500 630/800 800 1000 1250 1600
500V A 100 125 125/160 160 200 250 315 400 500 630/800 800 1000 1250 1600
690V A 100 125 125/160 160 200 250 315 400 500 630/800 800 1000 1250 1250
AC22A

Mixed resistive and inductive loads,
including moderate overloads

415V A 100 125 125/160 160 200 250 315 400 500 630/800 800 1000 1250 1600
500V A 100 125 125 160 200 250 315 400 400 630 800 1000 1250 1250
690V A 100 125 125 160 200 250 315 400 400 630 800 1000 1250 400
AC23A/B Switching of motor loads
or other highly inductive loads
(3 phase / 3 pole)
415V A 100 125 125 160 200 250 315 400 500 630 800 1000 1250 1250
500V A 80 100 100 125 160 200 250 315 315 500 800 800 800 800
690V A 63 80 80 100 125 160 200 250 250 400 400 400 400 400
AC23A Rated operational power 415V kW 52 65 65 85 105 130 165 200 210 330 420 525 630 630
Rated making capacity 415V
AC23
A 1000 1250 1250 1600 2000 2500 3150 4000 4000 6300 6300 6300 6300 6300
Rated breaking capacity 415V
AC23
A 800 1000 1000 1280 1600 2000 2520 3200 3200 5040 5040 5040 5040 5040
Short circuit withstand current 1 sec kA 5 5 5 8 8 8 13 13 13 26.5 35 35 35 60
Short circuit withstand current 0.25 sec kA 10 10 10 16 16 16 26 26 26 53 70 70 70 120
Short circuit making capcity 415V kA 7.5 7.5 7.5 13.5 13.5 13.5 26 26 26 30 73.5 73.5 73.5 105
Backup fuse A 100 125 160 160 200 250 315 400 400 630 800 1000 1000
R.M.S value kA 50 50 50 50 50 50 50 50 50 50 100 100 100
Peak value kA 12 15 16 16 20 25 25 30 30 40 70 90 100
Cable section mm2 35 50 70 120 120 120 185 2×150 2×150 2×185 2×240
Bars dimension mm 14×3 16×3 16×4 20×5 20×5 20×5 2x(25×4) 2x(25×4) 2x(25×4) 2x(32×6) 2x(50×5) 2x(50×6) 2x(50×8) 2x(80×102)