COMMAND 16A-160A

สวิตช์ตัดวงจรขนาด 16A ถึง 160A

Poles Y1 (R) Y1 (B) Y3 (B)
16A 2P 590.YA162R 590.YA162B
3P 590.YA163R 590.YA163B
3P+N 590.YA165R 590.YA165B
4P 590.YA164R 590.YA164B
6P 590.YA166B
8P 590.YA168B
20A 2P 590.YA202B
3P 590.YA203B
3P+N 590.YA205B
4P 590.YA204B
25A 6P 590.YA256B
8P 590.YA258B
32A 2P 590.YA322R 590.YA322B
3P 590.YA323R 590.YA323B
3P+N 590.YA325R 590.YA325B
4P 590.YA324R 590.YA324B
6P 590.YA326B
8P 590.YA328B
40A 2P 590.YA402R 590.YA402B
3P 590.YA403R 590.YA403B
3P+N 590.YA405R 590.YA405B
4P 590.YA404R 590.YA404B
6P 590.YA406B
8P 590.YA408B
Poles Y2 (R) Y2 (B) Y4 (B) Y5 (B)
63A 2P 590.YA632R 590.YA632B
3P 590.YA633R 590.YA633B
3P+N 590.YA635R 590.YA635B
4P 590.YA634R 590.YA634B
6P 590.YA636B
8P 590.YA638B
80A 2P 590.YA802R 590.YA802B
3P 590.YA803R 590.YA803B
3P+N 590.YA805R 590.YA805B
4P 590.YA804R 590.YA804B
6P 590.YA806B
8P 590.YA808B
100A 3P 590.YA1003R 590.YA1003B
3P+N 590.YA1005R 590.YA1005B
4P 590.YA1004R 590.YA1004B
6P 590.YA1006B
8P 590.YA1008B
125A 3P 590.YA1253B
3P+N 590.YA1255B
6P 590.YA1256B
8P 590.YA1258B
160A 3P 590.YA1603B
3P+N 590.YA1605B
6P 590.YA1606B
8P 590.YA1608B

TECHNICAL CHARACTERISTICS

2P, 3P, 3P+N & 4P

Switch size Y1 Y2 Y4 Y5
Rated current in 16A 20A 32A 40 63A 80A 100A 125A 160A
Rated insulation voltage                     Ui VAC 690 690 690 690 690 690 800 800 800
Rated impulse withstand voltage         Uimp kV 4 4 4 4 4 4 8 8 8
Thermal current                                 lth/lthe A 16 20 32 40 63 80 100 125 160
AC21A

Resistive loads,
including moderate overloads

415V A 16 20 32 40 63 80 100 125 160
500V A 16 20 32 32 63 80 100 125 160
690V A 16 20 32 32 63 80 100 125 160
AC22A Mixed resistive and
inductive loads, including
moderate overloads
415V A 16 20 32 40 63 80 100 125 160
500V A 16 20 32 32 63 80 100 125 160
690V A 16 20 32 32 63 80 125 160
AC23A Switching of motor loads
or other highly inductive loads
(3 phase / 3 pole)
415V A 16 20 32 35 63 67 100 125 160
500V A 16 20 25 25 40 67 125 125
690V A 16 20 25 25 30 38 100 100
AC23 Rated operational power (°) 415V A 7.5 9 15 18.5 33 37 46 55 69
AC3 squirrel-cage motor:
starting, switching off motor during
running (3 phase/ 3 pole)
415V A 18 18 25 28.5 40 55
690V A 12 18 20 25 32
DC22A Mixed resistive and inductive
loads, including moderate overloads
250V A 25(*) 32(*) 32(*)
600V A 10(*) 10(*) 10(*)
Rated short time withstand current      lcw (1s) A 400 400 400 400 1500 1500 1500 3000 3000
Conditional short circuit current          lp KAeff 10 10 10 10 10 10 30 50 50
Associate fuse size for conditional
short circuit current – Type gG
A 16 20 32 40 63 80 100 125 125
Flexible wire mm2 1.5-10 1.5-10 1.5-10 1.5-10 10-35 10-35 10-50 10-70 10-70
Rigid wire mm2 1.5-16 1.5-16 1.5-16 1.5-16 10-35 10-35 10-50 10-70 10-70

(*) Only 4P with 2+2 poles in series.
(°) This values are given for guidance and may vary according to the specifics provided by the motor manufacturer.

6P & 8P

Switch size Y3 Y4 Y5
Rated current in 16A 25A 32A 40A 63A 80A 100A 125A 160A
Rated insulation voltage                     Ui VAC 800 800 800 800 800 800 800 800 800
Rated impulse withstand voltage         Uimp kV 8 8 8 8 8 8 8 8 8
Thermal current                                 lth/lthe A 16 25 32 40 63 80 100 125 160
AC21A Resistive loads,
including moderate overloads
415V A 16 25 32 40 63 80 100 125 160
500V A 16 25 32 40 63 160 80 125 160
690V A 16 25 32 40 63 160 80 125 160
AC22A

Mixed resistive and inductive loads,
including moderate overloads

415V A 16 25 32 40 63 160 80 125 160
500V A 16 25 32 40 63 160 80 125 160
690V A 16 25 32 40 40 40 40 125 160
AC23A

Switching of motor loads or other
highly inductive loads (3 phase / 3 pole)

415V A 16 25 32 40 63 80 100 125 160
500V A 16 25 32 40 63 63 63 125 125
690V A 16 25 25 25 32 32 32 100 100
AC23 Rated operational power (°) 415V kW 7.5 11 15 18.5 35 37 46 55 69
Rated short time withstand current      lcw (1s) A 1100 1100 1100 1100 1500 1500 1500 3000 3000
Conditional short circuit current          lp KAeff 50 50 50 50 50 50 30 50 50
Associate fuse size for conditional
short circuit current –
Type gG
A 16 25 32 40 63 80 100 125 125
Flexible wire mm2 4-25 4-25 4-25 4-25 10-50 10-50 10-50 10-70 10-70
Rigid wire mm2 4-25 4-25 4-25 4-25 10-50 10-50 10-50 10-70 10-70

(°) This values are given for guidance and may vary according to the specifics provided by the motor manufacturer.

  • Y1, Y2 (R) Rear panel mounting screws fixing.
  • Y1, Y2 (B) Base mounting DIN rail fixing.
  • Y3, Y4, Y5 (B) Base mounting DIN rail fixing or screws fixing